Site Map

Products & Services



Heating and Cooling Stages


Application & Benefits

Cooling and heating systems provided by Micro-optik are extremely valuable tool for many non-ambient temperature experiments.

 

Example "melting plastic"

The advantages of this technique are greatly improved in combination with modern image and video recording technologies.

Hot and cold stage systems consist of a hot and cold stage, a STC200 Series standalone temperature controller, and WinTemp - a Windows based software.

 

Hot and Cold Stages for Upright Microscopes

Model

Temperature Range

Sample Chamber Area

Feature

WS60

ambient to 60°C
(95°C Optional)

25 x 75 mm (1 x 3")
and/or 60mm diameter

Compact size warm stage for 1" x 3" slides or 60mm petri dishes.

TS62

-30°C to 120°C

38 x 50 mm
(1.5 x 2")

Peltier based thermal stage for moderate temperature range applications.

TX102W

-30°C to 100°C

38 x 50 mm
(1.5 x 2")

Peltier based microscope thermal stage featuring a wide incident angle (60°) and a large viewing window (38mm dia).

TS64

-20°C to 90°C

88 x 88 mm
(3.5 x 3.5")

Peltier based thermal stage features extra-large sample area.

HCS302

-190°C to 400°C

38 x 50 mm
(1.5 x 2")

Single-heater thermal stage with wide temperature range for general purpose applications. Stage frame cooling using circulation water pump.

HCS402

-190°C to 400°C

38 x 50 mm
(1.5 x 2")

Dual-heater thermal stage, with heaters located both below and above the sample chamber for ultra temperature uniformity. Can be quickly converted to HCS302, the single-heater stage model. Stage frame cooling using circulation water pump.

HCS412W

-60°C to 400°C

38 x 50 mm
(1.5 x 2")

Dual-heater heating and cooling stage features large viewing aperture and wide incident angle.

FS1

-60°C to 200°C

38 x 50 mm
(1.5 x 2")

Dual-heater heating and cooling stage with large viewing aperture for thin film study. Includes thin film drawing kits with removable inner chamber for cleaning.

HS400

ambient to 400°C

38 x 50 mm
(1.5 x 2")

Dual-heater hot stage with ultra temperature uniformity. Built-in fan for air-cooling of the stage frame.

HCS410

-60°C to 400°C

38 x 50 mm
(1.5 x 2")

Dual-heater hot and cold stage, using the built-in fan for frame cooling. Similar to HS400, but also with sample chamber cooling capability.

HCS601

-190°C to 600°C
(700°C optional)

20 x 20 mm
(0.8 x 0.8")

Ultra high temperature hot and cold stage, with the option to extend to wider temperature range.

FCS611

-190°C to 600°C

20 x 20 mm
(0.8 x 0.8")

Ultra high temperature hot and cold stage systems with gas tight sample chamber, features eight (8) electric feed-through leads for sample probing.

FCS612

-190°C to 600°C

38 x 38 mm
(1.5 x 1.5")

HCS206

-40°C to 200°C

139 x 147 mm
(5.5 x 5.8")

Hot and cold stage designed for extra-large samples. Optional circulation water pump for frame cooling.

Hot and Cold Stages for Inverted Microscopes

Model

Temperature Range

Sample Chamber Area

Feature

HCS60

5°C to 60°C

35mm diameter

Peltier based thermal stage designed especially for inverted microscopes. Accepts 35mm petri dishes.

HCS61

5°C to 60°C
(Optional wider temp. range)

68 x 68 mm

Pelter based thermal stage features a large viewing aperture and large sample area. Optional lid for defrosting available. Accepts 60 mm petri dishes or 2"x3" slides.

HCD301

-80°C to 250°C

25 x 25 mm
(1 x 1")

Hot and cold stage specifically designed for use on inverted microscopes with a wide temperature range.

Thermal Vacuum Stages for Upright Microscopes

Model

Temperature Range

Sample Chamber Area

Feature

TS102V

-40°C to 90°C

25 x 88 mm
(1 x 3.5")

Peltier based thermoelectric freeze drying stage with sealed sample chamber for vacuum. Optional two (2) electric feed-through leads for sample probing.

HCS611V

-190°C to 600°C

20 x 20 mm
(0.8 x 0.8")

Ultra high temperature hot and cold vacuum stage systems with optional two (2) electric feed-through leads for sample probing.

HCS612V

-190°C to 600°C

38 x 38 mm
(1.5 x 1.5")

HCX611V

-190°C to 600°C

20 x 20 mm
(0.8 x 0.8")

Ultra high temperature hot and cold vacuum stage systems with built-in precision XY positioner to move sample inside the stage. Optional two (2) electric feed-through leads for sample probing.

HCX612V

-190°C to 600°C

38 x 38 mm
(1.5 x 1.5")

FCS611V

-190°C to 600°C

20 x 20 mm
(0.8 x 0.8")

Ultra high temperature hot and cold vacuum stage systems, features eight (8) electric feed-through leads for sample probing.

FCS612V

-190°C to 600°C

38 x 38 mm
(1.5 x 1.5")

- Information for STC200 Series Temperature Controller.

- Information for optional Cooling Accessories: Liquid Nitrogen Cooling Systems , Circulation Water Pumps

Contact Micro-optik today for complete product brochures. Inquiries for a hot and cold stage system customized to your special requirements are also welcome.



.: Bilogical Microscopes :. 

.: Stereo Microscopes :. 

.: KH :. 

.: DiMic :. 

.: DiMic Ultra zoom :. 

.: DiMic Topography :. 

.: Far-Eye :. 

.: High-Speed 3D Camera :. 

.: Micro-Eye :. 

.: Smart-Eye :. 

.: X-Loupe :. 

.: Dino-Lite :. 

.: Automation and Image Analysis :. 

.: Stand and Accesories :. 

.: Tailored software solutions :. 

.: Heating and Cooling Stages :. 

.: Solar Cell Inspection System :. 

.: Inspection and Analysis :. 

.: Advertisement Videos :. 

.: Engineering Services :. 

.: Scanning Electron Microscopy :. 

.: MIMAS :. 

.: Low Voltage Electron Microscopy :. 

.: NIR Industrial Spectrometers :. 



For any information, demonstration, tests or quotation, please send an email to: info@micro-optik.com

© 2010 Micro-optik